Visionary  solutions  to  water management  through technology
 

Specifications

1.0 BASIC RME SERIES FEATURES

1.1 Standard Programming Capability

The controller shall have:

 

1.2 Water Conservation Features

The controller shall have:

 

1.3 Convenience Features

The controller shall have:

1.4 Diagnostic and Fault Detection

The controller shall have:

 

2.0 FLOW CAPABILITIES

 The controller shall have:

3.0 EVAPOTRANSPIRATION (ET) FEATURES OF THE RME EAGLE

3.1 ET Operations

 The controller shall have:

  • Ability to enable or disable ET processing on a per program basis.
  • The ability to use any one of four different ET sources as the basis for its ET calculations:
    1. Historical ET data
    2. Manually entered ET data
    3. Rain Master ET measurement device or equivalent
    4. Downloaded ET data from the internet (requires optional hardware)
  • The ability to input and store Historical ET data on a monthly basis (12 months); the data is based on a daily average, at the geographic location of the controller.
  • The ability to store an ET reference value. This value is used during the adjusted station runtime ET calculations.
  • The ability to automatically re-compute the user entered station runtime, at the moment of irrigation, utilizing the current ET information. The station runtime is evaluated and adjusted based on days since last irrigation. The controller automatically compensates for changes in weather patterns between irrigation days.
  • Accept a manual operator entered weekly ET value. The manual entry will override previous entered or accumulated ET data. At the end of the seven day period the controller will automatic revert to utilizing Historic, device, or Internet provided daily ET data.
  • Connectivity to an ET measuring device such as a Rain Master Weather Station. The controller shall record .01 of an inch (ET ) each time a contact closure appears at the input. The contact closure shall be between .2 seconds and 2.3 seconds in duration. The controller shall source +5 VDC to the device.
  • The ability to display the last ET daily value including the source ( historical, measured, manually entered, or Internet ).
  • Ability to display the current adjusted runtime as a percent of the base runtime for all ET enabled programs.

4.0 AVAILABLE RME EAGLE OPTIONS

 The controller shall have:

EG-ST Series
Stainless steel,  expanded size field wiring cabinet.

5.0 MECHANICAL SPECIFICATIONS

6.0 ELECTRICAL SPECIFICATIONS

7.0 DOCUMENTATION

8.0 CERTIFICATION AND WARRANTY